CGA P-40

Original price was: $159.00.Current price is: $79.00.

Calculation Method for the Analysis and Prevention of Overpressure During Refilling of Cryogenic Tanks with Rupture Disk(s)

Compressed Gas Association , 09/06/2017

Preview

Category:

This publication provides technical guidance and the complete equation set needed to determine if a particular vessel can or cannot be overpressurized during the refill operation. Acceptable engineering controls for the protection of cryogenic storage tanks and transport tanks with rupture disk(s) as part of the relief system are provided. The application of these engineering controls constitutes a minimum standard.

The calculations in this publication may be used to evaluate each pumping system and cryogenic tank combination in use with oxygen, nitrogen, or argon. It applies to tanks filled either by pump from a cryogenic transport or by a ground-mounted pump. This applies to cryogenic tanks greater than 265 gal (1000 L) water capacity. This does not apply to cryogenic tanks with flat bottoms. For flat bottomed cryogenic tanks, refer to CGA P-8.9, Bulk Liquid Oxygen, Nitrogen, and Argon Storage Systems at Production Sites.

Original price was: $128.78.Current price is: $64.00.

Calculation Method for the Analysis and Prevention of Overpressure During Refilling of Cryogenic Storage Tanks, Third Edition

Compressed Gas Association , 04/29/2011

Preview

Category:
This publication provides technical guidance and the complete equation set needed to determine if a particular vessel can or cannot be overpressurized during the refill operation. Acceptable engineering controls for the protection of cryogenic storage tanks and transport tanks with rupture disk(s) as part of the relief system are provided. The application of these engineering controls constitutes a minimum standard.

The calculations in this publication should be used to evaluate each pumping system and cryogenic tank combination in use with oxygen, nitrogen, or argon. It applies to tanks filled either by pump from a cryogenic transport or by a ground-mounted pump. This applies to cryogenic tanks greater than 265 gal (1000 L) water capacity.

Original price was: $135.54.Current price is: $67.00.

Calculation Method for the Analysis and Prevention of Overpressure During Refilling of Cryogenic Storage Tanks, Second Edition

Compressed Gas Association , 09/07/2007

Category:
View contents.

Cryogenic storage tanks are normally refilled from transports that use high flow centrifugal pumping systems. These pumping systems are capable of pressures that exceed the tank’s maximum allowable working pressure and flow rates that may exceed the capacity of the tank’s pressure relief system.

This publication provides the complete equation set for determining the flow capacity of the tank’s pressure relief and filling systems based upon specific line sizes, valves, and other components. Formulas for sizing a flow-limiting orifice when required to restrict the fill rate to match the relief system are included. The publication includes a discussion of alternative solutions such as an external protection device as well as sample calculations.

It is the responsibility of each tank owner to ensure that pressure relief devices are properly sized for the tank refill operation.