CGA P-8.6

Original price was: $94.00.Current price is: $47.00.

Unmanned Air Gas Plants: Design and Operation

Compressed Gas Association , 04/29/2022

Preview

Category:

The purpose of this publication is to provide guidelines for the design, operation, and maintenance of a plant that has unmanned or remote operations.

Unmanned or remotely operated plant functionality can range from a plant with full remote functionality i.e., satellite plant controlled by a remote operating center (ROC) to a plant with autonomous operation.

The installations that are included in this publication are:

  • cryogenic air separation plants;
  • cryogenic nitrogen generators;
  • noncryogenic plants (pressure swing absorption, vacuum pressure swing absorption, membrane, etc.) for oxygen and nitrogen;
  • pipeline compression stations;
  • compressed dry air facilities; and
  • back-up systems and site storage, if existing and integrated with the production unit.

Specifically excluded are product supply tanks installed at a customer’s premises, home care units (for example, concentrators), and noncryogenic plants with a capacity of 5 ton (5 000 kg) per day or less. For noncryogenic plants from 5 ton to 20 ton (5 000 kg to 20 000 kg) per day, a risk assessment shall be carried out to identify which requirements of this publication apply.

Original price was: $78.00.Current price is: $39.00.

Unmanned Air Gas Plants – Design and Operation

Compressed Gas Association , 07/01/2015

Preview

Category:
The purpose of this publication is to provide guidelines for the design, operation, and maintenance of a plant that will have unmanned or remote operations.

Unmanned or remotely operated plant functionality can range from a plant with full remote functionality, i.e., satellite plant controlled by a remote operating center (ROC) to a plant with autonomous operation. The installations that are included in this publication are:

  • cryogenic air separation plants;
  • cryogenic nitrogen generators;
  • noncryogenic plants (pressure swing absorption, vacuum pressure swing absorption, membrane, etc.,) for oxygen and nitrogen;
  • pipeline compression stations;
  • compressed dry air facilities; and
  • back-up systems and site storage, if existing and integrated with the production unit.

Specifically excluded are product supply tanks installed at a customer

  • s premises, home care units (for example, concentrators), and noncryogenic plants with a capacity of 5 ton (5000 kg) per day or less. For noncryogenic plants from 5 ton (5000 kg) per day to 20 ton (20 000 kg) per day, a risk assessment shall be carried out to identify which requirements of this publication apply.