UL 217

Original price was: $255.09.Current price is: $127.00.

Smoke Alarms

Underwriters Laboratories , 01/02/2020

Category:
Please note: All interim revisions for this edition available at time of your purchase will be included.

Original price was: $156.05.Current price is: $78.00.

Smoke Alarms

Underwriters Laboratories , 06/03/2015

Category:
Smoke Alarms

UL 217

1 Scope

1.1 These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations and portable smoke alarms used as “travel” alarms in accordance with:

  • a) National Fire Alarm and Signaling Code, NFPA 72;
  • b) Standard for Recreational Vehicles, NFPA 501C, for smoke alarms intended for use in recreational vehicles;
  • c) For smoke alarms intended for use in recreational boats:
  • 1) Fire Protection Standard for Pleasure and Commercial Motor Craft, NFPA 302,
  • 2) AC and DC Electrical Systems on Boats, ABYC E-11, and
  • 3) The applicable regulations of the United States Coast Guard.

Original price was: $159.02.Current price is: $79.00.

Smoke Alarms

Underwriters Laboratories , 10/30/2015

Category:
Please note: All interim revisions for this edition available at time of your purchase will be included.

Smoke Alarms

UL 217

1 Scope

1.1 These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations and portable smoke alarms used as “travel” alarms in accordance with:

  • a) National Fire Alarm and Signaling Code, NFPA 72;
  • b) Standard for Recreational Vehicles, NFPA 501C, for smoke alarms intended for use in recreational vehicles;
  • c) For smoke alarms intended for use in recreational boats:
    • 1) Fire Protection Standard for Pleasure and Commercial Motor Craft, NFPA 302,
    • 2) AC and DC Electrical Systems on Boats, ABYC E-11, and
    • 3) The applicable regulations of the United States Coast Guard.

1.2 A single station smoke alarm (e.g. ionization-type, photoelectric-type, smoke alarm with supplementary heat detection type, combination smoke type, multi-criteria type), as defined by these requirements, is a self-contained fire alarm device that consists of an assembly of electrical components including a smoke sensor/ chamber, alarm sounding appliance, and provision for connection to a power supply source, either by splice leads, terminals, a cord and plug arrangement or containing integral batteries to detect one or more products of combustion. The products of combustion may consist of visible as well as invisible smoke particles, gases, heat, radiant energy, and water vapor. Additional functionality such as, a supplemental heat detector, terminals for connection to a remote audible signaling appliance (device) or accessory, and an integral transmitter to energize a remote audible signaling appliance (device) is permitted to be incorporated as part of the smoke alarm assembly.

1.3 Smoke-alarms not intended for interconnection are defined as single-station type.

1.4 Multiple station units are single station smoke alarms that are:

  • a) Interconnected so that actuation of one results in alarm sounding by all interconnected smoke alarms, or
  • b) Smoke alarms that are connected to remote heat detectors or heat alarms (thermostats).

1.5 These requirements, where applicable, also cover all remote accessories that are to be connected.

1.6 This standard does not cover the following:

  • a) Smoke detectors of the non-self-contained type that are intended for connection to a household or industrial system control unit. These are included in the Standard for Smoke Detectors for Fire Protective Signaling Systems, UL 268;
  • b) Mechanically operated single and multiple station fire alarm devices that are specified in the Standard for Single and Multiple Station Heat Alarms, UL 539;
  • c) Heat detectors – except for the requirements in the Fire Test (smoke alarm with heat detection) – Section 71) incorporated as part of a single station smoke alarm assembly whose requirements are covered in the Standard for Heat Detectors for Fire Alarm Signaling Systems, UL 521 and/or when part of a multi-criteria smoke alarm.
  • d) An accessory that is provided with a means to transmit alarm signals to a constantly attended, remote monitoring location. Any accessory capable of transmitting these types of signals is covered by the requirements in the Standard for Household Fire-Warning Sytem Units, UL 985;
  • e) A gas and vapor detector or sensor incorporated as a part of a smoke alarm assembly and covered by the Standard for Single and Multiple Station Carbon Monoxide Alarms, UL 2034, except when part of a multi-criteria smoke alarm.

Original price was: $234.84.Current price is: $117.00.

Single and Multiple Station Smoke Detectors

Underwriters Laboratories , 08/25/2006

Category:
Single and Multiple Station Smoke Alarms

UL 217

1 Scope

1.1 These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations of residential units in accordance with the National Fire Alarm Code, NFPA 72, smoke alarms intended for use in recreational vehicles in accordance with the Standard for Recreational Vehicles, NFPA 501C, smoke alarms intended for use in recreational boats in accordance with the Fire Protection Standard for Pleasure and Commercial Motor Craft NFPA 302, smoke alarms intended for use in detached one- and two-family dwellings and townhouses in accordance with the International Residential Code and portable smoke alarms used as “travel” alarms.

1.1 revised August 4, 2010

1.2 A single station smoke alarm, as defined by these requirements, is a self-contained fire alarm device that consists of an assembly of electrical components including a smoke chamber, alarm sounding appliance, and provision for connection to a power supply source, either by splice leads or a cord and plug arrangement or containing integral batteries. Possible accessories include a supplemental heat detector, terminals for connection to a remote audible signaling appliance or accessory, and an integral transmitter to energize a remote audible signaling appliance.

1.3 Multiple station units are single station smoke alarms that are either interconnected for common alarm annunciation or connected to remote thermostats.

1.4 These requirements, where applicable, also cover all remote accessories that are to be connected to or are intended to be used with a single or multiple station smoke alarm. See 33.2.1.

1.5 This standard does not cover the following:

a) Smoke detectors of the non-self-contained type that are intended for connection to a household or industrial system control unit. These are included in the Standard for Smoke Detectors for Fire Protective Signaling Systems, UL 268.

b) Mechanically operated single and multiple station fire alarm devices that are specified in the Standard for Single and Multiple Station Heat Alarms, UL 539.

c) Heat detectors [except for the requirements in the Fire Test (Heat Detector), Section 73] incorporated as part of a single station smoke alarm assembly whose requirements are covered in the Standard for Heat Detectors for Fire Alarm Signaling Systems, UL 521.