1 Scope

1.1 These requirements cover the following recirculating systems rated 600 volts or less and intended for indoor use:

a) Non-integral recirculating systems for installation in commercial establishments for the preparation of food;

b) Electric commercial cooking appliances provided with integral recirculating systems intended for installation in commercial establishments for the preparation of food; and

c) Vending machines provided with integral recirculating systems.

1.2 These devices incorporate an air filtering system enclosed in a hooded or otherwise contained area intended to capture air from the cooking process area. The hood assembly typically includes a fan, collection hood, or equivalent design and an air filtering system (consisting of a grease filter with or without other filtering means). In addition, except as noted in the Exceptions to 37.1 and 38.1, the hood assembly includes a fire actuated damper, and a fire extinguishing system.

1.3 Recirculating systems covered by these requirements are intended for installation in accordance with:

a) The Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96;

b) The National Electrical Code, ANSI/NFPA 70; and

c) Other codes such as the International Mechanical Code (IMC), and the Uniform Mechanical Code (UMC).

1.4 Integral recirculating systems shall comply with the requirements for the cooking appliance as noted below, except as modified or superseded by the requirements in this Standard.

a) Commercial electric cooking appliances shall comply with the requirements in the Standard for Commercial Electric Cooking Appliances, UL 197.

b) Vending machines shall comply with the requirements in the Standard for Vending Machines, UL 751.

Original price was: $242.43.Current price is: $121.00.

Standard for Recirculating Systems

Underwriters Laboratories , 09/03/2004

Category:
By order of the publisher, historical UL documents are not returnable for any reason. Once you place an order for an historical document, we cannot issue a refund, credit, or exchange of any kind.

These editorial revisions to UL 710B replace all references to UL 1020, the Standard for Thermal Cutoffs for Use in Electrical Appliances and Components, with reference to UL 60691, the Standard for Thermal-Links – Requirements and Application Guide. UL 1020 was withdrawn and superseded by UL 60691.

These requirements cover commercial electric cooking appliances provided with integral recirculating systems (previously referred to as ductless hoods) and nonintegral recirculating systems, both of which are intended for installation in commercial establishments for the preparation of food. These devices incorporate an air filtering system enclosed in a hooded or otherwise contained area intended to capture air from the cooking process area. The hood assembly generally includes a fan, collection hood, or equivalent design feature, air filtering system (consisting of a grease filter with other filters), a fire actuated damper, and a fire extinguishing system unit. An integral recirculating system of a vending machine is also covered by this supplement.