UL 962A
1 Scope
1.1 These requirements cover indoor use cord and plug connected furniture power distribution units (FPDU) rated 250 V AC or less and 20 Amperes or less. FPDU’s are for fixed mounting to furnishings as a power supply connection for cord and plug connected electrical utilization equipment in accordance with the National Electric Code, NFPA 70.
1.2 A cord and plug connected product as described in 1.1 with less than three receptacle outlets and provided with a Luminaire is covered under the Standard for Portable Electric Luminaires, UL 153.
1.3 A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs an electromagnetic interference filter is covered under the Standard for Electromagnetic Interference Filters, UL 1283.
1.4 A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs a surge protective device (SPD) is covered under the Standard for Surge Protective Devices, UL 1449.
1.5 A cord and plug connected product as described in 1.1 that employs ground-fault protection is covered under the requirements for portable GFCIs in the Standard for Ground-Fault Circuit Interrupters, UL 943.
1.6 This standard does not cover FPDU’s intended for use with medical equipment.
1.7 These requirements cover FPDU’s provided with isolated secondary circuits.
1.8 These requirements cover FPDU’s provided with batteries located in isolated secondary circuits.
1.9 A product that has a battery backup feature or other uninterruptible power supply equipment located in the Primary Circuit shall comply with the applicable requirements in the Standard for Uninterruptible Power Supply Equipment, UL 1778.
1.10 A FPDU with three or more receptacle outlets may employ a Light Emitting Diode (LED) Luminaire.
Original price was: $114.70.$57.00Current price is: $57.00.
Furniture Power Distribution Units
Underwriters Laboratories , 09/29/2014
UL 962A
1 Scope
1.1 These requirements cover indoor use cord and plug connected furniture power distribution units (FPDU) rated 250 V AC or less and 20 Amperes or less. FPDU’s are for fixed mounting to furnishings as a power supply connection for cord and plug connected electrical utilization equipment in accordance with the National Electric Code, NFPA 70.
1.2 A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs an electromagnetic interference filter is covered under the Standard for Electromagnetic Interference Filters, UL 1283.
1.3 A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs a surge protective device (SPD) is covered under the Standard for Surge Protective Devices, UL 1449.
1.4 A cord and plug connected product as described in 1.1 that employs ground-fault protection is covered under the requirements for portable GFCIs in the Standard for Ground-Fault Circuit Interrupters, UL 943.
1.5 This standard does not cover FPDU’s intended for use with medical equipment.

Original price was: $142.76.$71.00Current price is: $71.00.
Furniture Power Distribution Units
Underwriters Laboratories , 12/22/2008
UL 962A
1 Scope
1.1 These requirements cover cord-connected, indoor use, furniture power distribution units (FPDU) that consist of single or multiple outlet wiring devices that provide power for and are intended to be installed in commercial or household (residential) portable or stationary furnishings only. These units provide outlet receptacle(s) for computers, audio and video equipment, and other equipment that is mounted on or in commercial or household (residential) portable or stationary furnishings. These requirements also cover FPDUs that incorporate one attachment plug and a single length of flexible cord terminated in an enclosure in which receptacles may be mounted. Up to six lengths of flexible cord, not exceeding 1-1/2 ft (0.46 m) in length, may exit the enclosure with each length terminating in a separate, single cord connector. Furniture power distribution units may also be provided with fuses or other supplementary overcurrent protection, switches, suppression components, EMI filters, uninterruptible power supplies, and/or indicator lights in any combination, or connections for cable communications, telephone and/or antenna.
1.1 revised September 19, 2011
1.1.1 FPDUs are intended to be directly connected to a permanently installed branch circuit receptacle. FPDUs are not intended to be series connected (daisy chained) to other FPDUs, relocatable power taps, or to extension cords.
1.1.1 added September 19, 2011
1.2 These requirements cover products rated 250 V AC or less and 16 A AC or less.
1.3 These requirements do not cover products for use in fixed furnishings.
1.4 Furniture power distribution units are not intended to function as general use relocatable power taps.
1.5 A furniture power distribution unit that employs an electromagnetic interference filter shall also comply with the Standard for Electromagnetic Interference Filters, UL 1283.
1.6 A furniture power distribution unit that employs a transient voltage surge suppressor shall also comply with the Standard for Surge Protective Devices, UL 1449.
1.7 Telephone equipment and communication circuit protectors included in a furniture power distribution unit shall comply with the requirements in the Standard for Information Technology Equipment Safety – Part 1: General Requirements , UL 60950-1, and the requirements in the Standard for Secondary Protectors for Communications Circuits, UL 497A, respectively.
1.8 A furniture power distribution unit that incorporates an antenna discharge unit or provides antenna connections to a television, a high-voltage video product, or antenna shall comply with the applicable requirements in the Standard for Antenna-Discharge Units, UL 452, and the Standard for Audio-Video Products and Accessories, UL 1492.
1.9 A cord-connected product that employs ground-fault protection shall comply with the requirements in the Standard for Ground-Fault Circuit Interrupters, UL 943.
1.10 A product that employs an uninterruptible power supply shall comply with the requirements in the Standard for Uninterruptible Power Systems, UL 1778.

Original price was: $254.84.$127.00Current price is: $127.00.
Furniture Power Distribution Units
Underwriters Laboratories , 09/08/2003
This First Edition of UL 962A is being published to adopt the requirements as proposed in UL’s December 27, 2000 and September 5, 2002 bulletins.
1 Scope
1.1 These requirements cover cord-connected, indoor use, furniture power distribution units (FPDU) that consist of single or multiple outlet wiring devices that provide power for and are intended to be installed in commercial or household (residential) portable or stationary furnishings only. These units provide outlet receptacle(s) for computers, audio and video equipment, and other equipment that is mounted on or in commercial or household (residential) portable or stationary furnishings. Furniture power distribution units may also be provided with fuses or other supplementary overcurrent protection, switches, suppression components, EMI filters, uninterruptible power supplies, and/or indicator lights in any combination, or connections for cable communications, telephone and/or antenna. FPDUs are intended to be directly connected to a permanently installed branch circuit receptacle. FPDUs are not intended to be series connected (daisy chained) to other FPDUs, relocatable power taps, or to extension cords.